2022-05-21 20:25:03 +00:00
|
|
|
|
|
|
|
#Wires
|
|
|
|
[wires]
|
|
|
|
#Connector max input in FE/t (Energy transfer).
|
|
|
|
#Range: > 0
|
|
|
|
connector_max_input = 256
|
|
|
|
#Max wire length in blocks.
|
|
|
|
#Range: 0 ~ 256
|
|
|
|
wire_length = 12
|
|
|
|
#Connector max output in FE/t (Energy transfer).
|
|
|
|
#Range: > 0
|
|
|
|
connector_max_output = 256
|
|
|
|
#Connector internal input buffer in FE.
|
|
|
|
#Range: > 0
|
|
|
|
connector_input_capacity = 512
|
|
|
|
|
|
|
|
#General Settings
|
|
|
|
[general]
|
|
|
|
#Forge Energy conversion rate (in FE/t at max RPM).
|
|
|
|
#Range: > 0
|
|
|
|
fe_conversion = 240
|
|
|
|
#Max stress for the Alternator and Electric Motor (in SU at max RPM).
|
|
|
|
#Range: > 0
|
|
|
|
baseline_stress = 8192
|
|
|
|
|
|
|
|
#Charger (Deprecated)
|
|
|
|
[charger]
|
|
|
|
#Charger max input in FE/t (Energy transfer).
|
|
|
|
#Range: > 0
|
|
|
|
charger_max_input = 8192
|
|
|
|
#Charger charge rate in FE/t.
|
|
|
|
#Range: > 0
|
|
|
|
charger_charge_rate = 8192
|
|
|
|
#Charger internal capacity in FE.
|
|
|
|
#Range: > 0
|
|
|
|
charger_capacity = 32000
|
|
|
|
|
|
|
|
#Electric Motor
|
|
|
|
[electric_motor]
|
|
|
|
#Electric Motor internal capacity in FE.
|
|
|
|
#Range: > 0
|
|
|
|
motor_capacity = 2048
|
|
|
|
#Electric Motor minimum required energy consumption in FE/t.
|
|
|
|
#Range: > 0
|
|
|
|
motor_min_consumption = 8
|
|
|
|
#Electric Motor max input in FE (Energy transfer not consumption).
|
|
|
|
#Range: > 0
|
|
|
|
motor_max_input = 256
|
|
|
|
#Electric Motor min/max RPM.
|
|
|
|
#Range: > 1
|
|
|
|
motor_rpm_range = 256
|
|
|
|
|
|
|
|
#Heater
|
|
|
|
[heater]
|
|
|
|
#Enable Induction Heater when attached to a Furnace Engine.
|
|
|
|
heater_furnace_engine_enable = false
|
|
|
|
#Induction Heater internal capacity in FE.
|
|
|
|
#Range: > 0
|
|
|
|
heater_capacity = 2048
|
|
|
|
#Induction Heater max input in FE (Energy transfer, not consumption).
|
|
|
|
#Range: > 0
|
|
|
|
heater_max_input = 256
|
|
|
|
#Induction Heater normal consumption rate in FE/t.
|
|
|
|
#Range: > 0
|
|
|
|
heater_normal_consumption = 256
|
|
|
|
#Induction Heater when attached to a Furnace Engine consumption rate in FE/t.
|
|
|
|
#Range: > 0
|
|
|
|
heater_furnace_engine_consumption = 1024
|
|
|
|
|
|
|
|
#Tesla Coil
|
|
|
|
[tesla_coil]
|
|
|
|
#Tesla Coil charge rate in FE/t.
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_charge_rate = 4096
|
|
|
|
#Tesla Coil fire interval (in ticks).
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_fire_cooldown = 20
|
|
|
|
#Hurt range (in blocks/meters).
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_hurt_range = 3
|
|
|
|
#The chance that a AE2 Certus Quartz will be turned into Charged Certus Quartz for every tick.
|
|
|
|
#Range: 0.0 ~ 1.0
|
|
|
|
certus_quartz_charge_chance = 0.96
|
|
|
|
#Charger internal capacity in FE.
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_capacity = 32000
|
|
|
|
#Energy consumed when Tesla Coil is fired (in FE).
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_hurt_energy_required = 1024
|
|
|
|
#The duration of the Shocked effect for mobs (in ticks).
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_effect_time_mob = 20
|
|
|
|
#The duration of the Shocked effect for players (in ticks).
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_effect_time_player = 20
|
|
|
|
#Tesla Coil max input in FE/t (Energy transfer).
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_max_input = 8192
|
|
|
|
#Tesla Coil charge rate in FE/t for recipes.
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_recipe_charge_rate = 1024
|
|
|
|
#Damaged dealt to mobs when Tesla Coil is fired (in half hearts).
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_hurt_mob = 3
|
|
|
|
#Damaged dealt to players when Tesla Coil is fired (in half hearts).
|
|
|
|
#Range: > 0
|
|
|
|
tesla_coil_hurt_player = 2
|
|
|
|
|
|
|
|
#Alternator
|
|
|
|
[alternator]
|
|
|
|
#Alternator efficiency relative to base conversion rate.
|
|
|
|
#Range: 0.01 ~ 1.0
|
|
|
|
generator_efficiency = 0.75
|
|
|
|
#Alternator internal capacity in FE.
|
|
|
|
#Range: > 0
|
|
|
|
generator_capacity = 2048
|
|
|
|
#Alternator max input in FE (Energy transfer, not generation).
|
|
|
|
#Range: > 0
|
|
|
|
generator_max_output = 256
|
|
|
|
|
|
|
|
#Accumulator
|
|
|
|
[accumulator]
|
|
|
|
#Accumulator internal capacity in FE.
|
|
|
|
#Range: > 0
|
|
|
|
accumulator_capacity = 4196000
|
|
|
|
#Accumulator max output in FE/t (Energy transfer).
|
|
|
|
#Range: > 0
|
|
|
|
accumulator_max_output = 512
|
|
|
|
#Accumulator max input in FE/t (Energy transfer).
|
|
|
|
#Range: > 0
|
|
|
|
accumulator_max_input = 512
|
|
|
|
|
|
|
|
#Rolling Mill
|
|
|
|
[rolling_mill]
|
|
|
|
#Rolling Mill duration in ticks.
|
|
|
|
#Range: > 0
|
|
|
|
rolling_mill_processing_duration = 100
|
|
|
|
#Rolling Mill base stress impact.
|
|
|
|
#Range: 0 ~ 1024
|
|
|
|
rolling_mill_stress = 16
|
|
|
|
|
|
|
|
#Misc
|
|
|
|
[misc]
|
|
|
|
#Diamond Grit Sandpaper durability (number of uses).
|
|
|
|
#Range: > 3
|
|
|
|
diamond_grit_sandpaper_uses = 1024
|
|
|
|
#The relative speed of the Furnace Engine when powered by a Crude Burner.
|
|
|
|
#Range: 0.0 ~ 100.0
|
|
|
|
crude_burner_engine_speed = 2.0
|
|
|
|
#The energy cost of turning Chromatic Compound into Overcharged Alloy.
|
|
|
|
#Range: > 1
|
|
|
|
overcharging_energy_cost = 16777216
|
|
|
|
#The relative speed of the Furnace Engine when powered by a Furnace Burner.
|
|
|
|
#Range: 0.0 ~ 100.0
|
|
|
|
furnace_burner_engine_speed = 1.0
|
|
|
|
|